Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Magn Reson Imaging ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558490

RESUMO

BACKGROUND: Automated 4D flow MRI valvular flow quantification without time-consuming manual segmentation might improve workflow. PURPOSE: Compare automated valve segmentation (AS) to manual (MS), and manually corrected automated segmentation (AMS), in corrected atrioventricular septum defect (c-AVSD) patients and healthy volunteers, for assessing net forward volume (NFV) and regurgitation fraction (RF). STUDY TYPE: Retrospective. POPULATION: 27 c-AVSD patients (median, 23 years; interquartile range, 16-31 years) and 24 healthy volunteers (25 years; 12.5-36.5 years). FIELD STRENGTH/SEQUENCE: Whole-heart 4D flow MRI and cine steady-state free precession at 3T. ASSESSMENT: After automatic valve tracking, valve annuli were segmented on time-resolved reformatted trans-valvular velocity images by AS, MS, and AMS. NFV was calculated for all valves, and RF for right and left atrioventricular valves (RAVV and LAVV). NFV variation (standard deviation divided by mean NFV) and NFV differences (NFV difference of a valve vs. mean NFV of other valves) expressed internal NFV consistency. STATISTICAL TESTS: Comparisons between methods were assessed by Wilcoxon signed-rank tests, and intra/interobserver variability by intraclass correlation coefficients (ICCs). P < 0.05 was considered statistically significant, with multiple testing correction. RESULTS: AMS mean analysis time was significantly shorter compared with MS (5.3 ± 1.6 minutes vs. 9.1 ± 2.5 minutes). MS NFV variation (6.0%) was significantly smaller compared with AMS (6.3%), and AS (8.2%). Median NFV difference of RAVV, LAVV, PV, and AoV between segmentation methods ranged from -0.7-1.0 mL, -0.5-2.8 mL, -1.1-3.6 mL, and - 3.1--2.1 mL, respectively. Median RAVV and LAVV RF, between 7.1%-7.5% and 3.8%-4.3%, respectively, were not significantly different between methods. Intraobserver/interobserver agreement for AMS and MS was strong-to-excellent for NFV and RF (ICC ≥0.88). DATA CONCLUSION: MS demonstrates strongest internal consistency, followed closely by AMS, and AS. Automated segmentation, with or without manual correction, can be considered for 4D flow MRI valvular flow quantification. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

2.
Eur Heart J Case Rep ; 7(4): ytad130, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37090762

RESUMO

Background: It has been demonstrated that the rate of aortic dilatation is influenced by alteration of aortic hemodynamics, such as normalized flow displacement (FDN) and wall shear stress (WSS). However, the effects of ageing on aortic hemodynamics have not yet been described. Case summary: 4D-Flow MRI derived aorta hemodynamics were derived in the ascending aorta of a patient with ascending aortic aneurysm (mean ± standard deviation: 46 ± 1 mm) and a healthy volunteer (aortic diameter 30 ± 1 mm) with long-term follow-up of ten and eight years, respectively. At all timepoints, compared to the healthy volunteer, the patient demonstrated higher magnitudes of FDN (7% ± 1% vs. 3% ± 1%) and WSS angle (36° ± 3° vs. 24° ± 6°), and lower WSS magnitude (565 ± 100 mPa vs. 910 ± 115 mPa), axial WSS (426 ± 71 mPa vs. 800 ± 108 mPa) and circumferential WSS (297 ± 64 mPa vs. 340 ± 85 mPa). The patient and healthy volunteer demonstrated different aortic dilatation rates (regression slope ± standard error: 0.2 ± 0.1 vs. 0.1 ± 0.2 mm per year) and trends in FDN (0.1% ± 0.1% vs. 0.1% ± 0.2% per year), WSS magnitude (22 ± 9 vs. 35 ± 13 mPa per year), axial WSS (19 ± 4 vs. 37 ± 7 mPa per year), circumferential WSS (9 ± 8 vs. 5 ± 15 mPa per year), and WSS angle (-0.5° ± 0.4° vs. -0.8° ± 1.0° per year). Discussion: Aortic hemodynamic parameters are marginally affected by ageing and the aortic diameter in this case series. Since aortic hemodynamic parameters have been associated with aortic dilation by previous studies, the outcomes of the two subjects suggest that the aortic dilatation rate will remain constant while individuals are ageing and dilating.

3.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36342204

RESUMO

OBJECTIVES: To date, it is not known if 16-20-mm extracardiac conduits are outgrown during somatic growth from childhood to adolescence. This study aims to determine total cavopulmonary connection (TCPC) haemodynamics in adolescent Fontan patients at rest and during simulated exercise and to assess the relationship between conduit size and haemodynamics. METHODS: Patient-specific, magnetic resonance imaging-based computational fluid dynamic models of the TCPC were performed in 51 extracardiac Fontan patients with 16-20-mm conduits. Power loss, pressure gradient and normalized resistance were quantified in rest and during simulated exercise. The cross-sectional area (CSA) (mean and minimum) of the vessels of the TCPC was determined and normalized for flow rate (mm2/l/min). Peak (predicted) oxygen uptake was assessed. RESULTS: The median age was 16.2 years (Q1-Q3 14.0-18.2). The normalized mean conduit CSA was 35-73% smaller compared to the inferior and superior vena cava, hepatic veins and left/right pulmonary artery (all P < 0.001). The median TCPC pressure gradient was 0.7 mmHg (Q1-Q3 0.5-0.8) and 2.0 (Q1-Q3 1.4-2.6) during rest and simulated exercise, respectively. A moderate-strong inverse non-linear relationship was present between normalized mean conduit CSA and TCPC haemodynamics in rest and exercise. TCPC pressure gradients of ≥1.0 at rest and ≥3.0 mmHg during simulated exercise were observed in patients with a conduit CSA ≤ 45 mm2/l/min and favourable haemodynamics (<1 mmHg during both rest and exercise) in conduits ≥125 mm2/l/min. Normalized TCPC resistance correlated with (predicted) peak oxygen uptake. CONCLUSIONS: Extracardiac conduits of 16-20 mm have become relatively undersized in most adolescent Fontan patients leading to suboptimal haemodynamics.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Humanos , Adolescente , Criança , Veia Cava Superior/cirurgia , Artéria Pulmonar/cirurgia , Hemodinâmica , Oxigênio , Cardiopatias Congênitas/cirurgia
4.
J Cardiovasc Magn Reson ; 24(1): 21, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-35346249

RESUMO

AIM: This study explores the relationship between in vivo 4D flow cardiovascular magnetic resonance (CMR) derived blood flow energetics in the total cavopulmonary connection (TCPC), exercise capacity and CMR-derived liver fibrosis/congestion. BACKGROUND: The Fontan circulation, in which both caval veins are directly connected with the pulmonary arteries (i.e. the TCPC) is the palliative approach for single ventricle patients. Blood flow efficiency in the TCPC has been associated with exercise capacity and liver fibrosis using computational fluid dynamic modelling. 4D flow CMR allows for assessment of in vivo blood flow energetics, including kinetic energy (KE) and viscous energy loss rate (EL). METHODS: Fontan patients were prospectively evaluated between 2018 and 2021 using a comprehensive cardiovascular and liver CMR protocol, including 4D flow imaging of the TCPC. Peak oxygen consumption (VO2) was determined using cardiopulmonary exercise testing (CPET). Iron-corrected whole liver T1 (cT1) mapping was performed as a marker of liver fibrosis/congestion. KE and EL in the TCPC were computed from 4D flow CMR and normalized for inflow. Furthermore, blood flow energetics were compared between standardized segments of the TCPC. RESULTS: Sixty-two Fontan patients were included (53% male, 17.3 ± 5.1 years). Maximal effort CPET was obtained in 50 patients (peak VO2 27.1 ± 6.2 ml/kg/min, 56 ± 12% of predicted). Both KE and EL in the entire TCPC (n = 28) were significantly correlated with cT1 (r = 0.50, p = 0.006 and r = 0.39, p = 0.04, respectively), peak VO2 (r = - 0.61, p = 0.003 and r = - 0.54, p = 0.009, respectively) and % predicted peak VO2 (r = - 0.44, p = 0.04 and r = - 0.46, p = 0.03, respectively). Segmental analysis indicated that the most adverse flow energetics were found in the Fontan tunnel and left pulmonary artery. CONCLUSIONS: Adverse 4D flow CMR derived KE and EL in the TCPC correlate with decreased exercise capacity and increased levels of liver fibrosis/congestion. 4D flow CMR is promising as a non-invasive screening tool for identification of patients with adverse TCPC flow efficiency.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Tolerância ao Exercício , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/etiologia , Cirrose Hepática/cirurgia , Espectroscopia de Ressonância Magnética , Masculino , Valor Preditivo dos Testes
5.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-34747442

RESUMO

OBJECTIVES: Adequacy of 16-20mm extracardiac conduits for adolescent Fontan patients remains unknown. This study aims to evaluate conduit adequacy using the inferior vena cava (IVC)-conduit velocity mismatch factor along the respiratory cycle. METHODS: Real-time 2D flow MRI was prospectively acquired in 50 extracardiac (16-20mm conduits) Fontan patients (mean age 16.9 ± 4.5 years) at the subhepatic IVC, conduit and superior vena cava. Hepatic venous flow was determined by subtracting IVC flow from conduit flow. The cross-sectional area (CSA) was reported for each vessel. Mean flow and velocity was calculated during the average respiratory cycle, inspiration and expiration. The IVC-conduit velocity mismatch factor was determined as follows: Vconduit/VIVC, where V is the mean velocity. RESULTS: Median conduit CSA and IVC CSA were 221 mm2 (Q1-Q3 201-255) and 244 mm2 (Q1-Q3 203-265), respectively. From the IVC towards the conduit, flow rates increased significantly due to the entry of hepatic venous flow (IVC 1.9, Q1-Q3 1.5-2.2) versus conduit (3.3, Q1-Q3 2.5-4.0 l/min, P < 0.001). Consequently, mean velocity significantly increased (IVC 12 (Q1-Q3 11-14 cm/s) versus conduit 25 (Q1-Q3 17-31 cm/s), P < 0.001), resulting in a median IVC-conduit velocity mismatch of 1.8 (Q1-Q3 1.5-2.4), further augmenting during inspiration (median 2.3, Q1-Q3 1.8-3.0). IVC-conduit mismatch was inversely related to measured conduit size and positively correlated with conduit flow. The normalized IVC-conduit velocity mismatch factor during expiration and the entire respiratory cycle correlated with peak VO2 (r = -0.37, P = 0.014 and r = -0.31, P = 0.04, respectively). CONCLUSIONS: Important blood flow accelerations are observed from the IVC towards the conduit in adolescent Fontan patients, which is related to peak VO2. This study, therefore, raises concerns that implanted 16-20mm conduits have become undersized for older Fontan patients and future studies should clarify its effect on long-term outcome.


Assuntos
Técnica de Fontan , Adolescente , Adulto , Prótese Vascular , Criança , Técnica de Fontan/métodos , Hemodinâmica , Humanos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Veia Cava Superior/cirurgia , Adulto Jovem
6.
Magn Reson Med ; 87(5): 2398-2411, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34866236

RESUMO

PURPOSE: To assess errors associated with EPI-accelerated intracardiac 4D flow MRI (4DEPI) with EPI factor 5, compared with non-EPI gradient echo (4DGRE). METHODS: Three 3T MRI experiments were performed comparing 4DEPI to 4DGRE: steady flow through straight tubes, pulsatile flow in a left-ventricle phantom, and intracardiac flow in 10 healthy volunteers. For each experiment, 4DEPI was repeated with readout and blip phase-encoding gradient in different orientations, parallel or perpendicular to the flow direction. In vitro flow rates were compared with timed volumetric collection. In the left-ventricle phantom and in vivo, voxel-based speed and spatio-temporal median speed were compared between sequences, as well as mitral and aortic transvalvular net forward volume. RESULTS: In steady-flow phantoms, the flow rate error was largest (12%) for high velocity (>2 m/s) with 4DEPI readout gradient parallel to the flow. Voxel-based speed and median speed in the left-ventricle phantom were ≤5.5% different between sequences. In vivo, mean net forward volume inconsistency was largest (6.4 ± 8.5%) for 4DEPI with nonblip phase-encoding gradient parallel to the main flow. The difference in median speed for 4DEPI versus 4DGRE was largest (9%) when the 4DEPI readout gradient was parallel to the flow. CONCLUSIONS: Velocity and flow rate are inaccurate for 4DEPI with EPI factor 5 when flow is parallel to the readout or blip phase-encoding gradient. However, mean differences in flow rate, voxel-based speed, and spatio-temporal median speed were acceptable (≤10%) when comparing 4DEPI to 4DGRE for intracardiac flow in healthy volunteers.


Assuntos
Imagem Ecoplanar , Imageamento Tridimensional , Velocidade do Fluxo Sanguíneo , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
7.
Comput Biol Med ; 133: 104385, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33894502

RESUMO

Aortic aneurysm is associated with aberrant blood flow and wall shear stress (WSS). This can be studied by coupling magnetic resonance imaging (MRI) with computational fluid dynamics (CFD). For patient-specific simulations, extra attention should be given to the variation in segmentation of the MRI data-set and its effect on WSS. We performed CFD simulations of blood flow in the aorta for ten different volunteers and provided corresponding WSS distributions. The aorta of each volunteer was segmented four times. The same inlet and outlet boundary conditions were applied for all segmentation variations of each volunteer. Steady-state CFD simulations were performed with inlet flow based on phase-contrast MRI during peak systole. We show that the commonly used comparison of mean and maximal values of WSS, based on CFD in the different segments of the thoracic aorta, yields good to excellent correlation (0.78-0.95) for rescan and moderate to excellent correlation (0.64-1.00) for intra- and interobserver reproducibility. However, the effect of geometrical variations is higher for the voxel-to-voxel comparison of WSS. With this analysis method, the correlation for different segments of the whole aorta is poor to moderate (0.43-0.66) for rescan and poor to good (0.48-0.73) for intra- and interobserver reproducibility. Therefore, we advise being critical about the CFD results based on the MRI segmentations to avoid possible misinterpretation. While the global values of WSS are similar for different modalities, the variation of results is high when considering the local distributions.


Assuntos
Aorta Torácica , Hidrodinâmica , Aorta Torácica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Estresse Mecânico
8.
Sci Rep ; 11(1): 6507, 2021 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-33753790

RESUMO

Long scan times prohibit a widespread clinical applicability of 4D flow MRI in Fontan patients. As pulsatility in the Fontan pathway is minimal during the cardiac cycle, acquiring non-ECG gated 3D flow MRI may result in a reduction of scan time while accurately obtaining time-averaged clinical parameters in comparison with 2D and 4D flow MRI. Thirty-two Fontan patients prospectively underwent 2D (reference), 3D and 4D flow MRI of the Fontan pathway. Multiple clinical parameters were assessed from time-averaged flow rates, including the right-to-left pulmonary flow distribution (main endpoint) and systemic-to-pulmonary collateral flow (SPCF). A ten-fold reduction in scan time was achieved [4D flow 15.9 min (SD 2.7 min) and 3D flow 1.6 min (SD 7.8 s), p < 0.001] with a superior signal-to-noise ratio [mean ratio of SNRs 1.7 (0.8), p < 0.001] and vessel sharpness [mean ratio 1.2 (0.4), p = 0.01] with 3D flow. Compared to 2D flow, good-excellent agreement was shown for mean flow rates (ICC 0.82-0.96) and right-to-left pulmonary flow distribution (ICC 0.97). SPCF derived from 3D flow showed good agreement with that from 4D flow (ICC 0.86). 3D flow MRI allows for obtaining time-averaged flow rates and derived clinical parameters in the Fontan pathway with good-excellent agreement with 2D and 4D flow, but with a tenfold reduction in scan time and significantly improved image quality compared to 4D flow.


Assuntos
Técnica de Fontan/métodos , Hemodinâmica , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Adolescente , Criança , Feminino , Técnica de Fontan/efeitos adversos , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Imageamento por Ressonância Magnética/normas , Masculino , Complicações Pós-Operatórias/fisiopatologia , Razão Sinal-Ruído , Adulto Jovem
9.
Am J Physiol Heart Circ Physiol ; 320(4): H1687-H1698, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33635164

RESUMO

The purpose of this study was to directly assess (patho)physiology of intraventricular hemodynamic interplay between four-dimensional flow cardiovascular magnetic resonance imaging (4D Flow MRI)-derived vorticity with kinetic energy (KE) and viscous energy loss (EL) over the cardiac cycle and their association to ejection fraction (EF) and stroke volume (SV). Fifteen healthy subjects and thirty Fontan patients underwent whole heart 4D Flow MRI. Ventricular vorticity, KE, and EL were computed over systole (vorticity_volavg systole, KEavg systole, and ELavg systole) and diastole (vorticity_volavg diastole, KEavg diastole, and ELavg diastole). The association between vorticity_vol and KE and EL was tested by Spearman correlation. Fontan patients were grouped to normal and impaired EF groups. A significant correlation was found between SV and vorticity in healthy subjects (systolic: ρ = 0.84, P < 0.001; diastolic: ρ = 0.81, P < 0.001) and in Fontan patients (systolic: ρ = 0.61, P < 0.001; diastolic: ρ = 0.54, P = 0.002). Healthy subjects showed positive correlation between vorticity_vol versus KE (systole: ρ = 0.96, P < 0.001; diastole: ρ = 0.90, P < 0.001) and EL (systole: ρ = 0.85, P < 0.001; diastole: ρ = 0.84, P < 0.001). Fontan patients showed significantly elevated vorticity_vol compared with healthy subjects (vorticity_volavg systole: 3.1 [2.3-3.9] vs. 1.7 [1.3-2.4] L/s, P < 0.001; vorticity_volavg diastole: 3.1 [2.0-3.7] vs. 2.1 [1.6-2.8] L/s, P = 0.002). This elevated vorticity in Fontan patients showed strong association with KE (systole: ρ = 0.91, P < 0.001; diastole: ρ = 0.85, P < 0.001) and EL (systole: ρ = 0.82, P < 0.001; diastole: ρ = 0.89, P < 0.001). Fontan patients with normal EF showed significantly higher vorticity_volavg systole and ELavg systole, but significantly decreased KE avg diastole, in the presence of normal SV, compared with healthy subjects. Healthy subjects show strong physiological hemodynamic interplay between vorticity with KE and EL. Fontan patients demonstrate a pathophysiological hemodynamic interplay characterized by correlation of elevated vorticity with KE and EL in the presence of maintained normal stroke volume. Altered vorticity and energetic hemodynamics are found in the presence of normal EF in Fontan patients.NEW & NOTEWORTHY Physiologic intraventricular hemodynamic interplay/coupling is present in the healthy left ventricle between vorticity versus viscous energy loss and kinetic energy from four-dimensional flow cardiovascular magnetic resonance imaging (4D Flow MRI). Conversely, Fontan patients present compensatory pathophysiologic hemodynamic coupling by an increase in intraventricular vorticity that positively correlates to viscous energy loss and kinetic energy levels in the presence of maintained normal stroke volume. Altered vorticity and energetics are found in the presence of normal ejection fraction in Fontan patients.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/cirurgia , Hemodinâmica , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Função Ventricular , Adolescente , Fenômenos Biomecânicos , Estudos de Casos e Controles , Criança , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Imagem de Perfusão do Miocárdio , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
10.
J Magn Reson Imaging ; 53(4): 1268-1279, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33179389

RESUMO

BACKGROUND: Hemodynamic aorta parameters can be derived from 4D flow MRI, but this requires lumen segmentation. In both commercially available and research 4D flow MRI software tools, lumen segmentation is mostly (semi-)automatically performed and subsequently manually improved by an observer. Since the segmentation variability, together with 4D flow MRI data and image processing algorithms, will contribute to the reproducibility of patient-specific flow properties, the observer's lumen segmentation reproducibility and repeatability needs to be assessed. PURPOSE: To determine the interexamination, interobserver reproducibility, and intraobserver repeatability of aortic lumen segmentation on 4D flow MRI. STUDY TYPE: Prospective and retrospective. POPULATION: A healthy volunteer cohort of 10 subjects who underwent 4D flow MRI twice. Also, a clinical cohort of six subjects who underwent 4D flow MRI once. FIELD STRENGTH/SEQUENCE: 3T; time-resolved three-directional and 3D velocity-encoded sequence (4D flow MRI). ASSESSMENT: The thoracic aorta was segmented on the 4D flow MRI in five systolic phases. By positioning six planes perpendicular to a segmentation's centerline, the aorta was divided into five segments. The volume, surface area, centerline length, maximal diameter, and curvature radius were determined for each segment. STATISTICAL TESTS: To assess the reproducibility, the coefficient of variation (COV), Pearson correlation coefficient (r), and intraclass correlation coefficient (ICC) were calculated. RESULTS: The interexamination and interobserver reproducibility and intraobserver repeatability were comparable for each parameter. For both cohorts there was very good reproducibility and repeatability for volume, surface area, and centerline length (COV = 10-32%, r = 0.54-0.95 and ICC = 0.65-0.99), excellent reproducibility and repeatability for maximal diameter (COV = 3-11%, r = 0.94-0.99, ICC = 0.94-0.99), and good reproducibility and repeatability for curvature radius (COV = 25-62%, r = 0.73-0.95, ICC = 0.84-0.97). DATA CONCLUSION: This study demonstrated no major reproducibility and repeatability limitations for 4D flow MRI aortic lumen segmentation. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Aorta/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
J Magn Reson Imaging ; 51(4): 1105-1116, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31591799

RESUMO

BACKGROUND: Patients with transposition of the great arteries (TGA) have an altered aortic geometry after an arterial switch operation (ASO), with neo-aortic root dilatation as an important complication. Geometry-related aortic hemodynamics have been assumed to contribute to pathology of the ascending aorta (AAo). PURPOSE: To evaluate aortic flow displacement (FD) and regional wall shear stress (WSS) in relation to ascending neo-aortic geometry in children after ASO. STUDY TYPE: Prospective. POPULATION: Twenty-eight TGA patients after ASO and 10 healthy volunteers. FIELD STRENGTH/SEQUENCE: 3.0T/4D flow (segmented fast-spoiled echo pulse), noncontrast-enhanced MR angiography (Dixon), and anatomic images (SSFP). ASSESSMENT: Aortic diameters and body surface area-indexed aortic dimensions (Z-scores), normalized FD and planar ascending aortic WSS. STATISTICAL TESTS: Mann-Whitney and chi-square tests for differences in FD magnitude, WSS, and FD directionality between groups, respectively. Spearman rank correlation to assess the degree of association between aortic geometry, FD and WSS parameters. Shapiro-Wilk test to evaluate distribution normality on the absolute differences in octant location between FD and WSS. RESULTS: TGA patients showed a significantly dilated proximal AAo and relatively small mid-AAo dimensions at the level of the pulmonary arteries (Z-scores neo-aortic root: 4.38 ± 1.96 vs. 1.52 ± 0.70, P < 0.001; sinotubular junction: 3.48 ± 2.67 vs. 1.38 ± 1.30, P = 0.010; mid-AAo: 0.32 ± 3.06 vs. 1.69 ± 1.24, P = 0.001). FD magnitude was higher in TGA patients (neo-aortic root: 0.048 ± 0.027 vs. 0.021 ± 0.006, P < 0.001; sinotubular junction: 0.054 ± 0.037 vs. 0.029 ± 0.013, P < 0.05) and was related to the neo-aortic Z-score. Clear areas of higher WSS at the right and anterior aortic wall regions along the distal AAo were detected in TGA patients, most pronounced in those with relatively smaller mid-AAo diameters. DATA CONCLUSION: TGA-specific geometry related to the ASO, evidenced by neo-aortic root dilatation and a sudden change in vessel diameter at mid-AAo level, leads to more aortic flow asymmetry in the proximal AAo and WSS distribution with higher WSS at the right and anterior aortic wall regions along the distal AAo. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2020;51:1105-1116.


Assuntos
Transposição das Grandes Artérias , Transposição dos Grandes Vasos , Aorta/diagnóstico por imagem , Transposição das Grandes Artérias/efeitos adversos , Criança , Hemodinâmica , Humanos , Estudos Prospectivos , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia
12.
J Cardiovasc Magn Reson ; 21(1): 43, 2019 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-31340834

RESUMO

BACKGROUND: We hypothesize that dobutamine-induced stress impacts intracardiac hemodynamic parameters and that this may be linked to decreased exercise capacity in Fontan patients. Therefore, the purpose of this study was to assess the effect of pharmacologic stress on intraventricular kinetic energy (KE), viscous energy loss (EL) and vorticity from four-dimensional (4D) Flow cardiovascular magnetic resonance (CMR) imaging in Fontan patients and to study the association between stress response and exercise capacity. METHODS: Ten Fontan patients underwent whole-heart 4D flow CMR before and during 7.5 µg/kg/min dobutamine infusion and cardiopulmonary exercise testing (CPET) on the same day. Average ventricular KE, EL and vorticity were computed over systole, diastole and the total cardiac cycle (vorticity_volavg cycle, KEavg cycle, ELavg cycle). The relation to maximum oxygen uptake (VO2 max) from CPET was tested by Pearson's correlation or Spearman's rank correlation in case of non-normality of the data. RESULTS: Dobutamine stress caused a significant 88 ± 52% increase in KE (KEavg cycle: 1.8 ± 0.5 vs 3.3 ± 0.9 mJ, P < 0.001), a significant 108 ± 49% increase in EL (ELavg cycle: 0.9 ± 0.4 vs 1.9 ± 0.9 mW, P < 0.001) and a significant 27 ± 19% increase in vorticity (vorticity_volavg cycle: 3441 ± 899 vs 4394 ± 1322 mL/s, P = 0.002). All rest-stress differences (%) were negatively correlated to VO2 max (KEavg cycle: r = - 0.83, P = 0.003; ELavg cycle: r = - 0.80, P = 0.006; vorticity_volavg cycle: r = - 0.64, P = 0.047). CONCLUSIONS: 4D flow CMR-derived intraventricular kinetic energy, viscous energy loss and vorticity in Fontan patients increase during pharmacologic stress and show a negative correlation with exercise capacity measured by VO2 max.


Assuntos
Agonistas de Receptores Adrenérgicos beta 1/administração & dosagem , Circulação Coronária/efeitos dos fármacos , Dobutamina/administração & dosagem , Teste de Esforço , Tolerância ao Exercício/efeitos dos fármacos , Técnica de Fontan , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Hemodinâmica/efeitos dos fármacos , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos , Consumo de Oxigênio/efeitos dos fármacos , Adolescente , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
Eur Radiol Exp ; 3(1): 24, 2019 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-31222473

RESUMO

BACKGROUND: Coarctation patients before curative reconstruction are exposed to abnormal flow patterns which potentially could cause wall deterioration. This study evaluated the effect of age at correction on the pulse wave velocity (PWV) and peak wall shear stress (WSS) in adolescent patients with corrected coarctation. Effects of valve morphology and presence of reobstruction were also evaluated. METHODS: Twenty-one patients aged 13.7 ± 2.6 years (mean ± standard deviation) were included (bicuspid aortic valve, n = 14; reobstruction, n = 9). Mean age at correction was 1.0 ± 1.8 years. PWV was determined from two high-temporal through-plane phase-contrast magnetic resonance imaging (MRI) acquisitions, for two segments: ascending aorta plus aortic arch and descending aorta. WSS was determined from four-dimensional flow MRI. Peak WSS over five systolic phases was determined for ascending aorta, aortic arch, and descending aorta. RESULTS: Patients with tricuspid aortic valve showed a significant correlation between the age at correction and descending aorta PWV (rs = 0.80, p = 0.010). Significant differences were found between patients without and with reobstruction for peak WSS in the aortic arch (3.9 ± 1.3 Pa versus 6.5 ± 2.2 Pa, respectively; p = 0.003) and descending aorta (5.0 ± 1.3 Pa versus 6.7 ± 1.1 Pa, respectively; p = 0.005). CONCLUSIONS: A prolonged period of abnormal haemodynamic exposure may result in increased aortic wall stiffening. The increased peak WSS as results of a reobstruction possibly promotes different disease progression, which endorse longitudinal follow-up examination of corrected coarctation patients.


Assuntos
Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Imageamento por Ressonância Magnética , Adolescente , Fatores Etários , Coartação Aórtica/cirurgia , Fenômenos Biomecânicos , Criança , Feminino , Humanos , Masculino , Estudos Prospectivos , Análise de Onda de Pulso , Recidiva , Estresse Mecânico
14.
Eur Heart J Cardiovasc Imaging ; 20(3): 323-333, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30060051

RESUMO

AIMS: To non-invasively assess intraventricular viscous energy loss (EL) and proportionality to kinetic energy (KE) in Fontan patients using 4D flow magnetic resonance imaging (MRI) and compare to healthy controls. METHODS AND RESULTS: Thirty Fontan patients and 15 controls underwent 4D flow MRI. Ventricular EL was computed and normalized by end-diastolic volume (EDV). EL over the cardiac cycle (ELcycle) relative to the average kinetic energy (KEcycle) was quantified using a dimensionless index, ELindex (ELcycle/KEcycle). EL was significantly elevated in Fontan patients compared to controls (ELcycle/EDV: 3.7 vs. 2.6 J/m3, P = 0.001). Fontan patients with inflow of blood entering a ventricle, which leaves that ventricle through a ventricular septal defect to the aorta, defined as discordant inflow-to-outflow showed significantly higher EL compared to patients with inflow of blood into the same ventricle from which the blood is ejected into the aorta, defined as concordant inflow-to-outflow (ELcycle/EDV: 6.8 vs. 3.2 J/m3, P = 0.001). EL was not significantly different in Fontan patients with a systemic left vs. a systemic right ventricle (ELcycle/EDV: 3.5 vs. 3.6 J/m3, P = 0.91). ELindex was significantly elevated in Fontan patients compared to controls (ELindex: 0.4 vs. 0.2, P < 0.001). Highest ELindex was found in Fontan patients with discordant inflow-to-outflow compared to concordant inflow-to-outflow (0.5 vs. 0.3, P = 0.01). CONCLUSION: Fontan patients show disproportionate intraventricular EL relative to KE. Intraventricular EL is elevated in these patients compared to healthy controls, and highest EL is found in patients with discordant inflow-to-outflow.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Técnica de Fontan/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Prognóstico , Valores de Referência , Medição de Risco , Estatísticas não Paramétricas , Resultado do Tratamento
15.
Radiology ; 290(1): 70-78, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30375924

RESUMO

Purpose To compare four-dimensional flow MRI with automated valve tracking to manual valve tracking in patients with acquired or congenital heart disease and healthy volunteers. Materials and Methods In this retrospective study, data were collected from 114 patients and 46 volunteers who underwent four-dimensional flow MRI at 1.5 T or 3.0 T from 2006 through 2017. Among the 114 patients, 33 had acquired and 81 had congenital heart disease (median age, 17 years; interquartile range [IQR], 13-49 years), 51 (45%) were women, and 63 (55%) were men. Among the 46 volunteers (median age, 28 years; IQR, 22-36 years), there were 19 (41%) women and 27 (59%) men. Two orthogonal cine views of each valve were used for valve tracking. Wilcoxon signed-rank test was used to compare analysis times, net forward volumes (NFVs), and regurgitant fractions. Intra- and interobserver variability was tested by using intraclass correlation coefficients (ICCs). Results Analysis time was shorter for automated versus manual tracking (all patients, 14 minutes [IQR, 12-15 minutes] vs 25 minutes [IQR, 20-25 minutes]; P < .001). Although overall differences in NFV and regurgitant fraction were comparable between both methods, NFV variation over four valves was smaller for automated versus manual tracking (all patients, 4.9% [IQR, 3.3%-6.7%] vs 9.8% [IQR, 5.1%-14.7%], respectively; P < .001). Regurgitation severity was discordant for seven pulmonary valves, 22 mitral valves, and 21 tricuspid valves. Intra- and interobserver agreement for automated tracking was excellent for NFV assessment (intra- and interobserver, ICC ≥ 0.99) and strong to excellent for regurgitant fraction assessment (intraobserver, ICC ≥ 0.94; interobserver, ICC ≥ 0.89). Conclusion Automated valve tracking reduces analysis time and improves reliability of valvular flow quantification with four-dimensional flow MRI in patients with acquired or congenital heart disease and in healthy volunteers. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by François in this issue.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/fisiopatologia , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Criança , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
16.
MAGMA ; 31(5): 653-663, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29804208

RESUMO

OBJECTIVE: The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. MATERIALS AND METHODS: Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. RESULTS: Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. CONCLUSIONS: Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.


Assuntos
Aorta/diagnóstico por imagem , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Resistência ao Cisalhamento , Adulto , Aorta Torácica/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Adulto Jovem
18.
Int J Cardiovasc Imaging ; 34(6): 905-920, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29305740

RESUMO

The aim of the current study was to assess the scan-rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. ELindex was computed to measure the amount of EL relative to KE over diastole. Scan-rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, ELindex and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64-0.95] and coefficients of variation (CV) ≤ 25%. ELindex showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan-rescan reproducibility of volumetric vorticity showed good-excellent ICCs (0.83-0.95) with CVs ≤ 11%. In conclusion, the current study shows strong-excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless ELindex, which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.


Assuntos
Diástole/fisiologia , Coração/diagnóstico por imagem , Coração/fisiologia , Imageamento por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem Cardíaca/métodos , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
19.
J Magn Reson Imaging ; 47(1): 272-281, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28470915

RESUMO

PURPOSE: To validate three widely-used acceleration methods in four-dimensional (4D) flow cardiac MR; segmented 4D-spoiled-gradient-echo (4D-SPGR), 4D-echo-planar-imaging (4D-EPI), and 4D-k-t Broad-use Linear Acquisition Speed-up Technique (4D-k-t BLAST). MATERIALS AND METHODS: Acceleration methods were investigated in static/pulsatile phantoms and 25 volunteers on 1.5 Tesla MR systems. In phantoms, flow was quantified by 2D phase-contrast (PC), the three 4D flow methods and the time-beaker flow measurements. The later was used as the reference method. Peak velocity and flow assessment was done by means of all sequences. For peak velocity assessment 2D PC was used as the reference method. For flow assessment, consistency between mitral inflow and aortic outflow was investigated for all pulse-sequences. Visual grading of image quality/artifacts was performed on a four-point-scale (0 = no artifacts; 3 = nonevaluable). RESULTS: For the pulsatile phantom experiments, the mean error for 2D PC = 1.0 ± 1.1%, 4D-SPGR = 4.9 ± 1.3%, 4D-EPI = 7.6 ± 1.3% and 4D-k-t BLAST = 4.4 ± 1.9%. In vivo, acquisition time was shortest for 4D-EPI (4D-EPI = 8 ± 2 min versus 4D-SPGR = 9 ± 3 min, P < 0.05 and 4D-k-t BLAST = 9 ± 3 min, P = 0.29). 4D-EPI and 4D-k-t BLAST had minimal artifacts, while for 4D-SPGR, 40% of aortic valve/mitral valve (AV/MV) assessments scored 3 (nonevaluable). Peak velocity assessment using 4D-EPI demonstrated best correlation to 2D PC (AV:r = 0.78, P < 0.001; MV:r = 0.71, P < 0.001). Coefficient of variability (CV) for net forward flow (NFF) volume was least for 4D-EPI (7%) (2D PC:11%, 4D-SPGR: 29%, 4D-k-t BLAST: 30%, respectively). CONCLUSION: In phantom, all 4D flow techniques demonstrated mean error of less than 8%. 4D-EPI demonstrated the least susceptibility to artifacts, good image quality, modest agreement with the current reference standard for peak intra-cardiac velocities and the highest consistency of intra-cardiac flow quantifications. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:272-281.


Assuntos
Coração/diagnóstico por imagem , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Imagens de Fantasmas , Adulto , Valva Aórtica/diagnóstico por imagem , Artefatos , Velocidade do Fluxo Sanguíneo , Imagem Ecoplanar , Feminino , Voluntários Saudáveis , Ventrículos do Coração/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valores de Referência , Reprodutibilidade dos Testes , Sístole , Adulto Jovem
20.
Congenit Heart Dis ; 12(1): 40-48, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27425568

RESUMO

PURPOSE: To evaluate the inflow pattern and flow quantification in patients with functional univentricular heart after Fontan's operation using 4D flow magnetic resonance imaging (MRI) with streamline visualization when compared with the conventional 2D flow approach. METHOD: Seven patients with functional univentricular heart after Fontan's operation and twenty-three healthy controls underwent 4D flow MRI. In two orthogonal two-chamber planes, streamline visualization was applied, and inflow angles with peak inflow velocity (PIV) were measured. Transatrioventricular flow quantification was assessed using conventional 2D multiplanar reformation (MPR) and 4D MPR tracking the annulus and perpendicular to the streamline inflow at PIV, and they were validated with net forward aortic flow. RESULTS: Inflow angles at PIV in the patient group demonstrated wide variation of angles and directions when compared with the control group (P < .01). The use of 4D flow MRI with streamlines visualization in quantification of the transatrioventricular flow had smaller limits of agreement (2.2 ± 4.1 mL; 95% limit of agreement -5.9-10.3 mL) when compared with the static plane assessment from 2DFlow MRI (-2.2 ± 18.5 mL; 95% limit of agreement agreement -38.5-34.1 mL). Stronger correlation was present in the 4D flow between the aortic and trans-atrioventricular flow (R2 correlation in 4D flow: 0.893; in 2D flow: 0.786). CONCLUSIONS: Streamline visualization in 4D flow MRI confirmed variable atrioventricular inflow directions in patients with functional univentricular heart with previous Fontan's procedure. 4D flow aided generation of measurement planes according to the blood flood dynamics and has proven to be more accurate than the fixed plane 2D flow measurements when calculating flow quantifications.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Valvas Cardíacas/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Hemodinâmica , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Criança , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Valvas Cardíacas/fisiopatologia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Projetos Piloto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA